5
Special roofing materials
VELUX 75
80 mm
X + 40-60 mm
Y + 45 mm
Decra roofing panels
140 mm
25 mm
Use flashing EDW for installation of VELUX roof windows in roofs
with Decra roofing panels.
The lowest level of these roofing panels is below the top face of
battens. This means that window and flashing must be installed
correspondingly deeper in the roof.
Establish a recessed area around the window for the flashing. This
area must be 25 mm below the top face of the battens. Ensure sup-
port of the battens as their load capacity is reduced.
Note! If it is not possible to keep a full roofing panel below the roof
window, please contact VELUX.